CareOne Temple Touch Thermometer

CareOne Temple Touch Thermometer

1 ct pkg

Warnings

Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Details

CareOne® Temple Touch Thermometer. Proven clinical accuracy. Ideal for infants & children. Non-invasive readings. 6-second readout. Rx Our pharmacists recommend. Features: 6-second readout. One button operation. Non-invasive readings. Peak temperature tone. Memory recall of last reading. °F or °C settings. Beeps when measurement is complete. Automatic shut-off. Low battery indicator. Not made with natural rubber latex . Contents: Temple thermometer, 2 AAA batteries instructions and 1-year warranty. Meets ASTM standard E 1112. Thank you for purchasing the temple thermometer. Please read these instructions carefully to ensure proper use and safe operation of your thermometer. Digital display. Power button. Probe sensor. Battery compartment. Blood vessels. Heat/energy flow. Skin. The temple touch thermometer works by measuring the heat flow from the blood vessels to the skin. That measurement is then converted to a comparable body temperature. In the event of an malfunction or incorrect temperature measurement, the following warnings will be displayed: Problem/cause Solution The measured temperature is above 1. Turn the unit OFF and then ON again. 107.6°F (42°C). 2. Retake temperature. These are not device malfunctions. 3. If still reads HI this Indicates that the patient has a high fever; seek medical attention. The measured temperature is below 1. Turn the unit OFF and then ON again. 95°F(35°C). 2. Retake temperature. These are not device malfunctions 3.If still reads LO this Indicates that the patient has a Low body temperature; seek medical attention. The temperature is too cold or too 1. Verify that the room temperature within hot to operate product range 60.8°F-104°F (16°C-40 °C). 2. Retake temperature. Temperature did not register Turn the unit OFF, wait 2 minutes, turn it ON again Because of poor contact, patient and retake temperature. Movement or poor placement. Unit malfunctioned Do not use the thermometer- contact customer care. Low battery – Battery icon flashes. Battery is low; enough power remains for approximately 10 measurements. Drained battery- Battery icon is the only Battery is completely expired and must be replaced. Icon on the display and unit turns off. Product specifications: Measurement time - 6-8 seconds. Measurement site - temple area of forehead. Measurement range - 95.0 ° F - 107.6 °F (35 ° - 42 °C). Operating temperature - 60.8 °F - 104.0 °F (16 °C - 40 °C); humidity 15-95% (non condensing). Storage temperature - -4.0 °F - 122.0 °F (-20 °C - 50 °C); humidity 15-95% (non condensing). Measurement scale - Fahrenheit and Celsius. Memory - recall of last measurement taken. Battery - 2 AAA 1.5V batteries. Battery life - approximately 24 months; minimum of 1000 measurements. Automatic shut-off - approximately after 1 minute of non-use. Accuracy - complies with ASTM E 1112-00 standards. Display - liquid crystal display. Display resolution - LCD 0.63" x 0.44". Dimensions - 4.7" x 1.17" x 1". Weight - 1.3 ounces with batteries. Specifications are subject to change without notice. FCC statement Important information required by the FCC This device compiles with part 15 of the FCC Rules. Operation is subject to the following two conditions (1) this device may not cause undesirable operation. NOTE: This equipment has been tested and found to comply with the limits for a class B digital device pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit from that to which the receiver is connected. Consult the dealer on an experienced radio/TV technician for help. One-year limited warranty. Your temple thermometer is covered by the following limited warranty commencing upon the date of purchase, and subject to the following terms and conditions: The warrantor warrants that its temple thermometer will be free from defects in materials and workmanship under normal consumer usage for a period of one year for the original purchaser of the temple thermometer. Periodic maintenance, repair and replacement of parts due to normal wear and tear are excluded from coverage. Defects or damage that result from: (a) improper operation, storage, misuse or abuse, accident or neglect, such as physical damage (cracks, scratches, etc.) to the surface of the product resulting from misuse; (b) contact with liquid, water, rain, extreme humidity or heavy perspiration, sand, dirt or the like, extreme heat, or food; (c) use of the temple touch thermometer for commercial purposes or subjecting the temple touch thermometer to abnormal usage or conditions; or (d) other acts which are not the fault of the Warrantor, are excluded from coverage. This warranty does not cover batteries or other power sources that may be provided with, or used with the temple thermometer. If the digital thermometer fails to conform to this limited warranty, return the temple touch Attn: Repair Department, 1175.Lakeside Drive, Gurnee, IL, 60031. When returning a product, please also include: (i) a copy of your receipt, bill of sale or other comparable proof of purchase; (ii) a written description of the problem; and (iii) your name, address and telephone number. Carefully package the product to avoid any damage that may occur while in transit; shipping insurance with returned receipt is recommended. At our option, Veridian healthcare will repair or replace the unit found to be defective in materials or workmanship under normal consumer usage. The purchaser will be notified of any additional repairs required prior to completing the repair, and will be responsible for parts charges, if any, and repair charges not covered by this limited warranty. Except as provided for in this limited warranty, all express and implied warranties and conditions are disclaimed, including without limitation the implied warranties of merchantability and fitness for a particular purpose. The repair or replacement as provided under this limited warranty is the exclusive remedy of the consumer, and is provided in lieu of all other warranties, express or Implied. In no event shall Veridian healthcare be liable, whether in contract or tort (including negligence) for damages in excess of the purchase price of the product, or for any indirect, incidental, special or consequential damages of any kind, or for damages to, or loss of, other property or equipment or personal injuries to the full extent these damages may be disclaimed by law. Some states and jurisdictions do not allow the limitation or exclusion of incidental or consequential damages, or limitation on the length of an implied warranty, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state or from one jurisdiction to another. Quality guaranteed or your money back. Customer care help line toll free 866-326-1313 Mon-Fri 8:30 AM - 4:30 PM CST. © 2017 Ahold Licensing Sarl.

Care and cleaning instructions: Wipe the probe with an alcohol swab or a cotton swab moistened with 70% isopropyl alchol before & after each use After cleaning wait at least 2 minutes before taking a measurement for the unit to readjust to room temperature. Use only a soft dry cloth to clean the body of the thermometer (if necessary). Never use an abrasive cleanser or submerge the thermometer in water or other liquids. Do not expose the thermometer to extreme temperatures, humidity, direct sunlight or shock. Store at room temperature. Quick start tips: 1.Press and release the power button, wait 2-seconds. 2.Hold unit family to temple until a long single beep is heard, 6-8 seconds. 3.Results will be displayed on the screen. 4.Wait one minute before new measurement. 5.To alternate between °F and °C, Press and hold the power button. Please read these instructions carefully This product is not intended to diagnose or treat any health problem or disease and should not be used as a substitute for the consultation and advice of a physician or other medical professional. Thermometers should only be used under the supervision of an adult. Before use, it is recommended that the patient avoid eating, drinking, smoking or exercising for at least twenty minutes prior to talking a measurement. Never walk, run or talk during a measurement. Normal body temperature/fever indicator: Body temperature can vary from 97°F and 100.0°F and still be considered normal the medically accepted normal body temperature is 98.6°F Body temperature is commonly lower in the upon walking than at any point during the rest of an individual’s walking hours. Temperature readings will vary based on the body location point of the reading. Average ‘normal’ temperature ranges by measurements location site: Forehead 97.0°F-100.0°F (36.1°C-37.8°C) Oral 97.0°F-100.0°F (36.1°C-37.8°C) Rectal 97.3°F-100.4°F (36.3°C-38.0°C) Axillary 95.4°F-99.0°F (35.2°C-37.2°C) A fever is defined as a body temperature that is elevated above the normal or that person. It is important to determine what is normal for an individual before determining. If a fever is present. Tracking an individual’s temperature on a consistent basis, at the same body site and at the same time everyday when the person is well or healthy will help determine an individual’s normal temperature. Guidelines for temple measurements This thermometer is designed to measure the temperature at the forehead, in proximity to the temple area between the end of the eyebrow and the hairline. Do not place the thermometer on scar tissue, skin disorder, open sores or abrasions or patients in trauma. Consult your physician when using drug therapies that may elevate skin temperature in the forehead. Do not use skin exposed to direct sunlight, fireplace heat, air conditioner or fan air flow, or hot/cold compress therapies. Wait at least one minute between measurements to allow the unit sensor to readjust to room temperature. If the thermometer has been stored in an excessively cold or warm environment, allow the thermometer to adjust to the ambient room temperature before use. Performance and operation of this unit may be compromised if operated outside of the specified temperature and humidity operating ranges. Operating instructions: 1.Press and release the power button to activate the thermometer. 2.The unit will beep and the thermometer will perform a self-test, showing all the symbols on the display. 3.The last measurement taken will shown on the display. 4.Gently place the probe in the center of the temple area between the end of the eyebrow and the hairline. Maintain firm contact with the skin, hold the thermometer to ensure reliable results. 5.Do not press the power button again. The measurements will start automatically once the probe is in place and will take approximately 6-8 seconds. A running circle will appear on the display indicating the reading is in progress. 6. The unit will sound one long beep when the measurement is complete and the reading will appear on the display. 7. To turn the unit off, simply press the power button. The unit will automatically shut-off after approximately one minute. Note: if you take another measurement before 1 minute has elapsed, the device will perform a 10 to 0 countdown to allow the device to reset for a new measurement. Do not try to measure during this countdown. If you attempt to measure during the countdown time, the device will display the previous result, beep 8 times and turn itself off automatically. Setting the operating scale or °C. The device setting is by default Fahrenheit(°). To change the scale to°C, or back to °F. 1.While off, press and hold the power button for 5 seconds, on the screen you will see the icon (°F,°C) Changes. 2. Release the button, the hourglass icon will disappear in 5 seconds indicating that the device is ready for use. Memory recall: This unit includes a recall of the last measurement taken. When the unit is OFF, press the power button to turn the unit on, and release. After the self-test, the unit will briefly show the last reading on the display. Replacing the battery. This thermometer includes 2 AAA 1.5V Batteries. The low-battery symbol will appear on the top center of the display when the battery needs to be changed. 1. Carefully slide the battery cap away from the unit. 2. Replace the batteries, taking care to match the correct polarity. 3. Carefully replace the battery cap. 4. Do not dispose of used batteries in the trash. Consult your local recycling center for the proper way to dispose the batteries in your area. Keep used batteries away from children, pets and excessive heat. Troubleshooting/ Identifying display symbols Performance may be degraded should one or more of the following occur: Operation outside stated temperature and humidity range. Storage outside state temperature and humidity range. Mechanical shock. Patient temperature is below ambient temperature. The thermometer has been designed to display feedback-warnings to ensure proper usage and accurate temperature measurement. When an error appears the device will “beep” 5 times, and then the thermometer will turn off automatically.

Manufacturer

Ahold USA, Inc.

Address

Landover, MD 20785

Phone

1-877-846-9949